Customization: | Available |
---|---|
Installation Type: | According to Client Request |
Sensing Type: | Resistive |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification Name | Scope | Detection Condition |
R25(nominal resistance value) | 500Ω~5MΩ | Constant temperature 25ºC±0.05ºC |
R25 Permissible variance(%) | ±1,±2, ±3, ±5, ±10 | Constant temperature 25ºC±0.05ºC |
B25/50 (material coefficient)(thermal-sensitivity index) | 2500~5000K | Constant temperature 25ºC±0.05ºC Constant temperature 50ºC±0.05ºC |
B25/50 Value permissible variance(%) | ±1,±2 | Constant temperature 25ºC±0.05ºC Constant temperature 50ºC±0.05ºC |
∫(dissipation coefficient) | ≥0.8mw/ºC | Static in the air |
T(thermal time constant) | ≤25S | Static in the air |
Ta(Working temperature) | -40ºC~+120ºC | |
Pn (rated power) | 50mw | within working temperature |